Handshaking : XON/XOFF as well as CTS/RTS (hardware flow
control).
If you run an application with the bundled printer driver under
Windows and use the serial port, you should check the above
parameters and set the flow control to “Xon/Xoff” or “hardware”.
14.3.5 Parallel (Centronics)
The parallel port is a standard 36-pin Centronics. Its pin
assignments are listed as following.
Pin
Direction
Definition
Pin
Directio
n
Definition
1
In
/STROBE
13
Out
SELECT
2
In
Data 1
14,15
NC
3
In
Data 2
16
-
Ground
4
In
Data 3
17
-
Ground
5
In
Data 4
18
NC
6
In
Data 5
19~3
0
-
Ground
7
In
Data 6
31
NC
8
In
Data 7
32
Out
/Fault
9
In
Data 8
33~3
6
-
NC
10
Out
/ACK
11
Out
BUSY
12
Out
PE
Seitenansicht 59