PT-Basic Programming Manual Ver. 1.00 46/143
READER_SENDCMD
Purpose
To send scanner (CCD) command to change scanner status.
Syntax
A%=READER_SENDCMD(N1% , N2% , S$)
Example
READER_CONFIG_START
„Code-39 can read
A%=READER_SENDCMD(11,1, CHR$(1))
„Code-93 Checksum verification disable
A%=READER_SENDCMD(12,2, CHR$(0))
„Preamble characters setting
A%=READER_SENDCMD(8,3, “abcde”)
READER_CONFIG_END
Description
This command can change scanner status.
A% is an integer variable to be assigned to the result.
A%
Meaning
0
Change fail
1
Change OK
N1% is an integer variable, indicating the parameter1.
N2% is an integer variable, indicating the parameter2.
S$ is a string variable.
Refer to Appendix Bfor more details about the parameter
setting.
READER_SENDCMD_LASER
Purpose
To send scanner (Laser) command to change scanner status.
Syntax
A%=READER_SENDCMD_LASER(N1% , N2% , S$)
Example
READER_CONFIG_START
„Code-39 can read
A%=READER_SENDCMD_LASER(11,1, CHR$(1))
„Preamble characters setting
A%=READER_SENDCMD_LASER (8,3, “abcde”)
READER_CONFIG_END
Description
This command can change scanner status.
A% is an integer variable to be assigned to the result.
A%
Meaning
Seitenansicht 46